Part Number70400-UL
Description: NORTH AMERICAN IN-LINE GFCI CONNECTOR, MANUAL RESET, 20 AMPERE-120 VOLT, (2400 WATTS) 60Hz (CLASS A), 4-6mA TRIP, TEST / RESET BUTTONS, 2 POLE-3 WIRE GROUNDING (2P+E), IMPACT RESISTANT BODY, RAINPROOF. BLACK.
Notes:
* 25 Millisecond maximum trip time.
* Terminals accept 18, 16, 14, 12 AWG conductors. Strain relief accepts 0.300-0.470" diameter cord.
* Temp. range = -35°C to +66°C.
* Requires “reset” after a power failure. Not for use on freezers, refrigerators, medical or other equipment where power must be maintained.
* GFCI (RCD) outlets, sockets, receptacles, In-line connectors, extension cords, circuit breakers listed below in related products. Scroll down to view.
Approvals: C(UL)US LISTED
Certifications: RoHS
Standards: UL 943, CSA C22.2
Technical Data:
View Technical Data Drawing: 70400-UL.pdf
Price & Avail: Contact Sales Office for Price and Delivery: Quantity Discount Incentives Available - Majority of all Products are in Stock
NORTH AMERICAN IN-LINE GFCI CONNECTOR, MANUAL RESET, 20 AMPERE-120 VOLT, (2400 WATTS) 60Hz (CLASS A), 4-6mA TRIP, TEST / RESET BUTTONS, 2 POLE-3 WIRE GROUNDING (2P+E), IMPACT RESISTANT BODY, RAINPROOF. BLACK. 

<br><font color="yellow">Notes: </font> 
<br><font color="yellow">*</font> 25 Millisecond maximum trip time.
<br><font color="yellow">*</font> Terminals accept 18, 16, 14, 12 AWG conductors. Strain relief accepts 0.300-0.470" diameter cord.
<br><font color="yellow">*</font> Temp. range = -35°C to +66°C.
<br><font color="yellow">*</font> Requires “reset” after a power failure. Not for use on freezers, refrigerators, medical or other equipment where power must be maintained.
<br><font color="yellow">*</font> GFCI (RCD) outlets, sockets, receptacles, In-line connectors, extension cords, circuit breakers listed below in related products. Scroll down to view.
Scroll down to view
Related Products
Related Products:

70400-UL

NORTH AMERICAN IN-LINE GFCI CONNECTOR, 20A-120V, (2400 WATTS) 60Hz (CLASS A), 4-6mA TRIP, MANUAL RESET, RAINPROOF. BLACK.
Notes:
* Requires “reset” after a power failure. Not for use on freezers, refrigerators, medical or other equipment where power must be maintained.

70400-ULAR

NORTH AMERICAN IN-LINE GFCI CONNECTOR, 15A-120V, (2400 WATTS) 60Hz (CLASS A), 4-6mA TRIP, AUTOMATIC RESET, RAINPROOF. BLACK.
Notes:
* No reset required after a power failure. Not for use on power tools, machines, equipment or other applications considered hazardous on automatic start up.

1597-I

15A-125V NEMA 5-15R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. IVORY.

1597-W

15A-125V NEMA 5-15R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. WHITE.

1597-BK

15A-125V NEMA 5-15R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. BLACK.

2097-I

20A-125V NEMA 5-20R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. IVORY.

2097-W

20A-125V NEMA 5-20R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A , SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. WHITE.

2097-BK

20A-125V NEMA 5-20R GFCI DUPLEX OUTLET, 4mA-6mA TRIP, CLASS A, SHUTTERED CONTACTS, AUTOMATIC CIRCUIT TEST, ON / OFF LIGHT & TRIP INDICATOR, IMPACT RESISTANT NYLON. BLACK.

92105-WPV

AMERICAN GFCI OUTLET WEATHERPROOF COVER, VERTICAL MOUNT, GASKETED, GRAY.
Notes:
* Mounts on American 2x4 size wall boxes.

92105-WPH

AMERICAN GFCI OUTLET WEATHERPROOF COVER, HORIZONTAL MOUNT, GASKETED, GRAY.
Notes:
* Mounts on American 2x4 size wall boxes.

5266-GFCI

GFCI PLUG, 15A-120V VOLT 60Hz, NEMA 5-15P, 4-6mA TRIP, CLASS A, RAINPROOF, TEST / RESET BUTTONS, ON / OFF INDICATOR, ACCEPTS 18AWG-12AWG CONDUCTORS, CORD GRIP RANGE 0.358-0.480". BLACK.
Notes:
* Connects with NEMA 5-15R 15A-125V & NEMA 5-20R 20A-125V outlets.

5366-GFCI

GFCI PLUG, 20A-120V VOLT 60Hz, NEMA 5-20P, 4-6mA TRIP, CLASS A, RAINPROOF, TEST / RESET BUTTONS, ON / OFF INDICATOR, ACCEPTS 18AWG-12AWG CONDUCTORS, CORD GRIP RANGE 0.358-0.480". BLACK.
Notes:
* NEMA 5-15P (15A-120V) version available #5266-GFCI.

70140-RCD30

EUROPEAN SCHUKO PLUG, CEE 7/7 GFCI RCD, 16A-230V, TYPE E, F PLUG (EU1-16P), 50Hz, 30mA TRIP, IP54 RATED, REWIREABLE ANGLE PLUG, BLACK.

70140-RCD10

EUROPEAN SCHUKO PLUG, 16A-230V (3680 WATTS), 50Hz, GFCI /RCD (PRCD-S) 10mA TRIP TYPE E, F PLUG, CEE 7/7 (EU1-16P), IP54 RATED, REWIREABLE ANGLE PLUG, BLACK.

70200x45

EUROPEAN (SCHUKO) GFCI (RCBO/RCD) OUTLET, 16A-250V, 50/60 Hz, 10mA TRIP, CEE 7/3 TYPE F (EU1-16R), SHUTTERED CONTACTS, TEST / RESET BUTTON, INDICATOR LIGHT, FLUSH MOUNTS ON STANDARD AMERICAN 2 GANG WALL BOX. WHITE.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, no reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-10HG

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) (EU1-16R) OUTLET, 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30HG

EUROPEAN SCHUKO 16A-230V CEE 7/3 GFCI (RCBO/RCD) (EU1-16R) OUTLET, 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY). GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

71200x45

FRANCE, BELGIUM GFCI (RCBO/RCD) OUTLET, 16A-230V, 50/60 Hz, 10mA TRIP, CEE 7/5 TYPE E (FR1-16R), SHUTTERED CONTACTS, TEST / RESET BUTTON, INDICATOR LIGHT, FLUSH MOUNTS ON STANDARD AMERICAN 2 GANG WALL BOX. WHITE.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

71225

FRANCE, BELGIUM GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (10mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm. Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

71225-30

FRANCE, BELGIUM GFCI GFCI (RCBO/RCD) 16 AMPERE-230 VOLT OUTLET, CEE 7/5 TYPE E (FR1-16R), 50/60 Hz, (30mA TRIP), HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER (GLAND TYPE CABLE ENTRY (**) . GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Screw terminal torque = 0.08Nm. Operating temp. = -5°C to +40°C.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

70200x45-IT

EUROPEAN (SCHUKO), ITALY, CHILE, S. AMERICA GFCI (RCBO/RCD) OUTLET, 16A-230V, 50/60 Hz, 10mA TRIP, CEE 7/3 TYPE F (EU1-16R), TYPE L, (IT1-10R/IT2-16R), CEI 23-50 (S17) CEI 23-16, SHUTTERED CONTACTS, TEST / RESET BUTTON, INDICATOR LIGHT, FLUSH MOUNTS ON STANDARD AMERICAN 2 GANG WALL BOX. WHITE.
Notes:
* Accepts type E, F European CEE 7, CEE 7/4, CEE 7/7 plugs, Euro CEE plugs, Italy, Chile type L 10 Ampere / 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-10-IT

EUROPEAN SCHUKO, ITALY, CHILE, SOUTH AMERICA GFCI (RCBO/RCD) OUTLET, 16A-230V, CEE 7/3 TYPE E, F, (EU1-16R), TYPE L, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (10mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED WEATHERPROOF BOX / COVER, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts Type E, F European CEE 7, CEE 7/4, CEE 7/7 plugs & Italy, Chile type L 10 Ampere & 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

70225-30-IT

EUROPEAN SCHUKO, ITALY, CHILE, SOUTH AMERICA GFCI (RCBO/RCD) OUTLET, 16A-230V, CEE 7/3 TYPE E, F, (EU1-16R), TYPE L, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (30mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED WEATHERPROOF BOX / COVER, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts Type E, F European CEE 7, CEE 7/4, CEE 7/7 plugs & Italy, Chile type L 10 Ampere & 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries. Contact us.

72140-RCD

UK, BRITISH, UNITED KINGDOM PLUG, 13A-240V (GFCI /RCD) PRCD-S, 30mA TRIP, IP44 BS 1363A TYPE G PLUG (UK1-13P), FUSED 13 AMP., REWIREABLE ANGLE PLUG, BLACK.
Notes:
* GFCI/RCD plug requires "Reset" after a power failure. Not for use on life support medical equipment, refrigerators, freezers or other applications where power must be maintained.

72300-DS-10MA

BRITISH, UNITED KINGDOM 13 AMPERE-230 VOLT, 50Hz, GFCI [RCD] DUPLEX OUTLET, [UK1-13R], 10mA TRIP , BS 1363 TYPE G SOCKETS, SHUTTERED CONTACTS, (86mmX146mm)SIZE, PANEL MOUNT, WALL BOX MOUNT. WHITE.
Notes:
* Outlet mounts on European, British wall boxes with 120mm (120.6mm) centers.
* European wall boxes available # 72355X47D, 72355X35D, 72355X25D, 72355-F, 72365, 72365-RED.
* Passive design [automatic reset], will not trip on power failure.
* Weatherproof enclosure available # 74790-B2 [IP66 rated], Cover closes & locks over down angle plugs [Not all plug variations].
* Weatherproof cover available # 74790-DX [IP54 rated], weatherproofs outlets only [less mating plugs]. Contact sales for details.
* Not for use on life support, medical equipment, refrigeration equipment.

72300-WPD-10MA

BRITISH, UNITED KINGDOM 13A-250V WEATHERPROOF GFCI (RCD) DUPLEX OUTLET, 10mA TRIP , IP66 RATED (COVER CLOSED) (**) , 50Hz, BS 1363 (UK1-13R) TYPE G SOCKETS, SHUTTERED CONTACTS, IMPACT RESISTANT. GRAY.
Notes:
** Cover can be closed & locked over down angle plugs (not all angle plug variations).
* M20 knockout cable entries (top, bottom, sides), "Earth" grounding terminals.
* Passive design [automatic reset], will not trip on power failure.
* Not for use on life support, medical equipment, refrigeration equipment.

72300-S-10MA

BRITISH, UNITED KINGDOM 13 AMPERE-230 VOLT, 50Hz, GFCI (RCD) OUTLET, (UK1-13R), 10mA TRIP , BS 1363 TYPE G SOCKETS, SHUTTERED CONTACTS, PANEL MOUNT, WALL BOX MOUNT, (86mmX86mm SIZE), 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Passive design [automatic reset], will not trip on power failure.
* International wall boxes. Use # 72350X47D, # 72350X35D, # 72350-F, # 72360 series.
* Weatherproof enclosure available #74790-B1 (IP66 rated). Cover can be closed & locked over down angle plugs (not all angle plug variations).
* Not for use on life support, medical equipment, refrigeration equipment.

72300-WPS-10MA

BRITISH, UNITED KINGDOM 13A-250V WEATHERPROOF GFCI (RCD) OUTLET, 10mA TRIP , IP66 RATED (COVER CLOSED) (**) , 50Hz, BS 1363 (UK1-13R) TYPE G SOCKETS, SHUTTERED CONTACTS, IMPACT RESISTANT. GRAY.
Notes:
** Cover can be closed & locked over down angle plugs (not all angle plug variations).
* M20 knockout cable entries (top, bottom, sides), "Earth" grounding terminals.
* Enclosure UV stabilized PC, Temp. rating = -5°C to +40°C.
* Passive design [automatic reset], will not trip on power failure.
* Not for use on life support, medical equipment, refrigeration equipment.

72300-S-UV

UNIVERSAL INTERNATIONAL, EUROPEAN, BRITISH, AUSTRALIA, CHINA, ASIA, THAILAND MULTI-CONFIGURATION 16 AMPERE-250 VOLT, 50-60Hz, GFCI (SRCD) OUTLET, 10mA TRIP, IP54 RATED, DOUBLE POLE TRIP, SHUTTERED CONTACTS, WALL BOX MOUNT OR PANEL MOUNT, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* 86mmX86mm SIZE, Mounts on European wall boxes with 60mm (60.3mm) centers,
* European wall boxes available #72350X47D, 72350X35D, 72355X35DDG, 72350-F, 72360.
* Not for use with weatherproof enclosures #74790 and #74790-A, #74790-B1.
* Passive design automatic reset, will not trip on power failure.
* Not for use on life support, medical equipment, refrigeration equipment.

72325-D

BRITISH, UNITED KINGDOM BS 1363, SAUDIA ARABIA SASO 2203 13A-230V GFCI RCBO/RCD DUPLEX OUTLET, TYPE G (UK1-13R, SA1-13R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, WEATHERPROOF, IP55 RATED, HORIZONTAL SURFACE MOUNT WALL BOX, GLAND TYPE CABLE ENTRY, CLEAR LIFT LID COVERS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets listed below. Scroll down to view.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI RCBO/RCD outlets are available for all countries. Contact us.

74140-RCD

AUSTRALIA / NEW ZEALAND PLUG, 10A-240V (GFCI /RCD) (AU1-10P), 30mA TRIP, REWIREABLE ANGLE PLUG, ACCEPTS 0.250-0.375" DIA. CORD. BLACK.
Notes:
* Plug connects with 10 Ampere, 15 Ampere, 20 Ampere Australian, New Zealand outlets, receptacles, connectors.

74200-NS

AUSTRALIAN / NEW ZEALAND 10 AMPERE 230-240 VOLT, 50Hz, GFCI/RCD, 10mA TRIP DUPLEX OUTLET (AU1-10R) AS/NZS 3112, SHUTTERED CONTACTS, ON/OFF SWITCHES, INDICATOR LIGHT, INTEGRAL WALL PLATE, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Mounts on American 2x4 wall boxes & International wall boxes with 39/32" (83mm / 84mm) mounting centers.
* Surface mounts on # 74225, # 84225-AR wall boxes or panel mount.
* Australia TUV approved building wire/cable #CNCP07AA002.
* GFCI/RCD allows for protection of downstream outlets.
* Not for use on life support, medical equipment, refrigeration equipment.

74335-10

AUSTRALIAN / NEW ZEALAND 10A-230V GFCI (RCBO/RCD) OUTLET (AU1-10R), 50/60 Hz, (10mA TRIP), IP55, SURFACE MOUNT. GRAY.

75525

ITALY, CHILE, SOUTH AMERICA 10A/16A-230V GFCI (RCBO/RCD) TYPE L DUPLEX OUTLET, CEI 23-50 (S17) CEI 23-16 (IT1-10R/IT2-16R) (10mA TRIP), 50/60Hz, SHUTTERED CONTACTS, IP55 RATED ENCLOSURE, HORIZONTAL SURFACE MOUNT, GLAND TYPE CABLE ENTRY (**). GRAY.
Notes:
* Accepts Italy, Chile Type L 10 Ampere, 16 Ampere plugs.
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* Weatherproof IP66 rated outlets available.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

76225x45

SWITZERLAND 10A-230V GFCI (RCBO/RCD) OUTLET SEV 1011, T13 TYPE (SW1-10R), 50/60 Hz 10mA TRIP, FLUSH MOUNTS TO AMERICAN 2 GANG WALL BOXES. WHITE.

76225

SWITZERLAND 10A-230V GFCI (RCBO/RCD) OUTLET SEV 1011, T13 TYPE (SW1-10R), 50/60 Hz 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.

78225x45

DENMARK 13A-250V GFCI (RCBO/RCD) TYPE K OUTLET (DE1-13R), 50/60 Hz, 10mA TRIP. WHITE. FLUSH MOUNTS ON AMERICAN 2 GANG WALL BOXES.

78225

DENMARK 13A-230V GFCI (RCBO/RCD) TYPE K OUTLET, (DE1-13R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.

73225x45

SOUTH AFRICA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, BS 546 TYPE M (UK1-15R, 6 AMPERE-250 VOLT OUTLET, TYPE D (UK3-5R , 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Flush mounts to American 2 gang 4x4 wall boxes.

73225

SOUTH AFRICA 16 AMPERE-230 VOLT GFCI (RCBO/RCD) OUTLET, BS 546 / TYPE M (UK1-15R), 6 AMPERE-250 VOLT OUTLET, TYPE D (UK3-5R), 50/60 Hz, 10mA TRIP, SHUTTERED CONTACTS, 2 POLE-3 WIRE GROUNDING (2P+E), IP55 RATED WEATHERPROOF BOX AND COVER, (GLAND TYPE CABLE ENTRY **), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Accepts South Africa 25A-250V, 16A-250V type M, 6A-250V type D plugs.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.

74725x45

CHINA 10 AMPERE-230 VOLT GFCI (RCBO/RCD), TYPE I (CH1-10R), 10mA TRIP, 50/60 Hz, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Flush mounts on American 4X4 wall box.
* Outlet accepts 10 ampere (CH1-10P) China plugs only.

74725

CHINA 10A-230V GFCI (RCBO/RCD) OUTLET (CH1-10R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Protects Downstream outlets.
* No reset after power failure (Latched RCD).
* Outlet accepts 10 ampere (CH1-10P) China plugs only.

85225x45

BRAZIL 10A-230V GFCI (RCBO/RCD) OUTLET, TYPE N, NBR 14136 (BR2-10R), 50/60 Hz 10mA TRIP. WHITE.
NOTES:
* Mounts on American 4X4 wall boxes.
* Outlet accepts Brazil 10A-250V, 2.5A-250V plugs, Power Cords.

85225

BRAZIL 10A-230V GFCI (RCBO/RCD) OUTLET, NBR 14136 TYPE N (BR2-10R), 50/60 Hz 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
NOTES:
* Outlet accepts Brazil 10A-250V, 2.5A-250V plugs, Power Cords.

77225x45

ISRAEL 16A-230V GFCI (RCBO/RCD) OUTLET, SI 32 (IS1-16R), 10mA TRIP, 50/60 Hz, WHITE.
* Mounts on American 4X4 wall boxes.

77225

ISRAEL 16A-230V GFCI (RCBO/RCD) OUTLET, SI 32 (IS1-16R), 10mA TRIP, 50/60 Hz, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.

70400-10MA

INTERNATIONAL IN-LINE GFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 10mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.

70400-30MA

INTERNATIONAL IN-LINEGFCI (RCCB/RCD) PRCD-S 16A-230V, 50Hz, 30mA TRIP, IP55 WEATHERPROOF IN-LINE CONNECTOR, MANUAL RESET. BLACK.

36050-RCD

EUROPEAN SCHUKO GFCI / RCD 16 AMPERE-250 VOLT IP44 RATED EXTENSION CORD, SCHUKO CEE 7/7 GFCI /RCD 30mA TRIP "DOWN ANGLE" (EU1-16P) TYPE E PLUG, TEST / RESET BUTTON, SCHUKO CEE 7/3 (EU1-16R) TYPE F CONNECTOR WITH WEATHERPROOF CLOSURE COVER, 15.24 METERS (50 FEET) (600") LONG. BLACK.
Length: 15.24 METERS (50 FEET)
Notes:
* GFCI / RCD Plug extension cord length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT , - 10MA Trip Versions .
* GFCI / RCD Inline Versions: 36025-RCDS10 , * Standard Versions: 36025 , * Weatherproof Versions: 36025-WP .

36050-RCDS10

EUROPEAN SCHUKO GFCI / RCD 16 AMPERE-250 VOLT IP44 RATED EXTENSION CORD, SCHUKO CEE 7/7 (EU1-16P) TYPE E PLUG WITH "IN-LINE" GFCI /RCD, 10mA TRIP, TEST/RESET BUTTON, SCHUKO CEE 7/3 (EU1-16R) TYPE F CONNECTOR WITH WEATHERPROOF CLOSURE COVER, 15.24 METERS (50 FEET) (600") LONG. BLACK.
Length: 15.24 METERS (50 FEET)
Notes:
* GFCI / RCD 10MA Trip Inline length options. Select: 6FT - 10FT - 15FT - 25FT - 50FT - 75FT - 100FT , - 30MA Trip Versions .
* GFCI / RCD Plug Versions: 36025-RCD , * Standard Versions: 36025 , * Weatherproof Versions: 36025-WP .

74458x45

EUROPEAN GFCI / RCBO CIRCUIT BREAKER, (RCD / GFCI WITH OVER CURRENT PROTECTION), 16 AMPERE-230 VOLT, SINGLE POLE + NEUTRAL, 50/60 HZ, 10mA TRIP, 45mmX45mm MODULAR SIZE, TEST/BUTTON, INDICATOR LIGHT, WALL BOX, PANEL, DIN RAIL MOUNT. WHITE.
Notes:
* Mounts on American 2X4 wall boxes, requires frame # 79120X45-N & # 79130X45-N wall plate (White, Black, ALU, SS).
* Mounts on American 4X4 wall boxes, requires frame # 79210X45-N & # 79220X45-N wall plate (White, SS).
* Mounts on European (60mm on center) wall boxes, requires frame # 79250X45-N & wall plate # 79265X45-N.
* Panel mount frame # 79100X45. DIN rail mount Frame # 79595X45. Panel Mount Instruction Guide
* Surface mount boxes, Flush mount boxes, IP66 / IP55 Enclosures & GFCI / RCD European / International power outlets available.
* Complete range of modular devices and mounting component options. Modular Devices Link

007879

EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE + NEUTRAL, 16A-230V CIRCUIT BREAKER (OVERLOAD & GFCI PROTECTION), 10mA TRIP, 2 MODULE SIZE, DIN RAIL MOUNT.GRAY.

236211

EUROPEAN / INTERNATIONAL GFCI RCBO 16 AMPERE-230 VOLT, COMBINED GFCI (RCD) & MCB (OVERLOAD) C-CURVE CIRCUIT BREAKER, 50HZ, 10mA TRIP, SINGLE POLE+NEUTRAL (1P+N) (2 MODULE SIZE), DIN RAIL MOUNT. GRAY.

EAD16BH30

EUROPEAN / INTERNATIONAL GFCI "RCBO" SINGLE POLE 16A-230V, 50Hz CIRCUIT BREAKER, 30mA TRIP, DIN RAIL MOUNT.