Part Number | 84225-30HG |
Description: | ARGENTINA 10 AMPERE-230 VOLT RCD/RCBO (GFCI) OUTLET (AR1-10R), 50/60 Hz, (30mA TRIP), 2 POLE-3 WIRE GROUNDING, HORIZONTAL SURFACE MOUNT, IP55 RATED WEATHERPROOF BOX AND COVER, OPERATING TEMP. = -5°C TO +40°C, TERMINAL TORQUE = 0.08Nm. GRAY. |
Certifications: | RoHS, CE |
Standards: | IRAM 2073, IP55 |
Technical Data: | View Technical Data Drawing: 84225-30HG.pdf |
Price & Avail: | Contact Sales Office for Price and Delivery: Quantity Discount Incentives Available - Majority of all Products are in Stock |
Scroll down to view
Related Products
Related Products
Related Products:
74725
CHINA 10A-230V GFCI (RCBO/RCD) OUTLET (CH1-10R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Protects Downstream outlets.
* No reset after power failure (Latched RCD).
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
74725-30
CHINA 10A-230V GFCI (RCBO/RCD) OUTLET (CH1-10R), 50/60 Hz, 30mA TRIP, IP55, HORIZONTAL MOUNT. GRAY.
Notes:
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
74725-10HH
CHINA 10A-250V GFCI (RCBO/RCD) OUTLET, TYPE I (CH1-10R), 50/60 Hz, 10mA TRIP, IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (*), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
74900-RCDS
UNIVERSAL EUROPEAN, INTERNATIONAL ASIA, AUSTRALIA, THAILAND CHINA MULTI-CONFIGURATION GFCI (RCD) OUTLET, 20 AMP 250 VOLT, 6mA TRIP , TEST / RESET BUTTONS, INDICATOR LIGHT, WHITE.
Notes:
* Mounts on American 2x4 wall boxes & International wall boxes with 3.28" (83mm / 84mm) mounting centers.
* Surface mounts on # 74225, # 84225-AR wall boxes or panel mount. Weatherproof horizontal mount cover # 74900-MCS
* Accepts Australia, China, South America Thailand, Asia, Israel, American plugs & European plugs with (4.8mm pins / 4.0mm pins).
* For use on International, European 220-250 volt (line to neutral) single phase circuits only. Protects downstream outlets.
* Not for use on life support, medical equipment, refrigeration equipment.
85100-RCD
MULTI-CONFIGURATION SOUTH AMERICA, EUROPEAN, AUSTRALIA, THAILAND, CHINA, ASIA, AMERICAN, INTERNATIONAL 16 AMPERE 220-250 VOLT, 6mA TRIP, DUPLEX GFCI (RCD) OUTLET, INDICATOR LIGHT, TEST/RESET BUTTONS, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Mounts on American 2x4 wall boxes & International wall boxes with 39/32" (83mm / 84mm) mounting centers.
* Surface mounts on # 74225, # 84225-AR wall boxes or panel mount. Weatherproof horizontal mount cover # 74900-MCS
* Accepts Australia, China, South America Thailand, Asia, Israel, American plugs & European plugs with (4.8mm pins / 4.0mm pins).
* For use on International, European 220-250 volt (line to neutral) single phase circuits only.
* Protects downstream outlets.
* Not for use on life support, medical equipment, refrigeration equipment.
74325-10HG
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI [RCBO/RCD] OUTLET, 13A-230V, 50/60 Hz, [10mA TRIP], TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY [**], HORIZONTAL SURFACE MOUNT, GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO [single pole + neutral] provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
74325-30HG
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
74325-10HGD
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD)DUPLEX OUTLET, 13A-230V, 50/60 Hz, (10mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 250 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.
74325-30HGD
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD)DUPLEX OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 250 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.
4731-10HG2
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) OUTLET, 13A-230V, 50/60 Hz, (10mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP20 RATED, GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
4731-30HG2
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP 20 RATED, GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" Designs and IP66 rated versions available. GFCI (RCBO/RCD) Outlets are available for all countries.
4731-10HG3
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) DUPLEX OUTLET, 13A-230V, 50/60 Hz, (10mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP 20 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.
4731-30HG3
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) DUPLEX OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP 20 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.
74725
CHINA 10A-230V GFCI (RCBO/RCD) OUTLET (CH1-10R), 50/60 Hz, 10mA TRIP, IP55 RATED, HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Protects Downstream outlets.
* No reset after power failure (Latched RCD).
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
74725-30
CHINA 10A-230V GFCI (RCBO/RCD) OUTLET (CH1-10R), 50/60 Hz, 30mA TRIP, IP55, HORIZONTAL MOUNT. GRAY.
Notes:
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
74725-10HH
CHINA 10A-250V GFCI (RCBO/RCD) OUTLET, TYPE I (CH1-10R), 50/60 Hz, 10mA TRIP, IP55 RATED WEATHERPROOF BOX AND COVER, M20 CABLE ENTRY HUBS (*), HORIZONTAL SURFACE MOUNT. GRAY.
Notes:
* Outlet accepts 10 ampere (CH1-10P) China plugs only.
74900-RCDS
UNIVERSAL EUROPEAN, INTERNATIONAL ASIA, AUSTRALIA, THAILAND CHINA MULTI-CONFIGURATION GFCI (RCD) OUTLET, 20 AMP 250 VOLT, 6mA TRIP , TEST / RESET BUTTONS, INDICATOR LIGHT, WHITE.
Notes:
* Mounts on American 2x4 wall boxes & International wall boxes with 3.28" (83mm / 84mm) mounting centers.
* Surface mounts on # 74225, # 84225-AR wall boxes or panel mount. Weatherproof horizontal mount cover # 74900-MCS
* Accepts Australia, China, South America Thailand, Asia, Israel, American plugs & European plugs with (4.8mm pins / 4.0mm pins).
* For use on International, European 220-250 volt (line to neutral) single phase circuits only. Protects downstream outlets.
* Not for use on life support, medical equipment, refrigeration equipment.
85100-RCD
MULTI-CONFIGURATION SOUTH AMERICA, EUROPEAN, AUSTRALIA, THAILAND, CHINA, ASIA, AMERICAN, INTERNATIONAL 16 AMPERE 220-250 VOLT, 6mA TRIP, DUPLEX GFCI (RCD) OUTLET, INDICATOR LIGHT, TEST/RESET BUTTONS, 2 POLE-3 WIRE GROUNDING (2P+E). WHITE.
Notes:
* Mounts on American 2x4 wall boxes & International wall boxes with 39/32" (83mm / 84mm) mounting centers.
* Surface mounts on # 74225, # 84225-AR wall boxes or panel mount. Weatherproof horizontal mount cover # 74900-MCS
* Accepts Australia, China, South America Thailand, Asia, Israel, American plugs & European plugs with (4.8mm pins / 4.0mm pins).
* For use on International, European 220-250 volt (line to neutral) single phase circuits only.
* Protects downstream outlets.
* Not for use on life support, medical equipment, refrigeration equipment.
74325-10HG
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI [RCBO/RCD] OUTLET, 13A-230V, 50/60 Hz, [10mA TRIP], TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY [**], HORIZONTAL SURFACE MOUNT, GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO [single pole + neutral] provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
74325-30HG
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
74325-10HGD
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD)DUPLEX OUTLET, 13A-230V, 50/60 Hz, (10mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 250 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.
74325-30HGD
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD)DUPLEX OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP55 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 250 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.
4731-10HG2
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) OUTLET, 13A-230V, 50/60 Hz, (10mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP20 RATED, GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" designs and IP66 rated versions available. GFCI (RCBO/RCD) outlets are available for all countries.
4731-30HG2
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP 20 RATED, GLAND TYPE CABLE ENTRY (**), HORIZONTAL SURFACE MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
** M20 "Hub Entry" Designs and IP66 rated versions available. GFCI (RCBO/RCD) Outlets are available for all countries.
4731-10HG3
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) DUPLEX OUTLET, 13A-230V, 50/60 Hz, (10mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP 20 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.
4731-30HG3
UNIVERSAL, INTERNATIONAL, MULTI-CONFIGURATION GFCI (RCBO/RCD) DUPLEX OUTLET, 13A-230V, 50/60 Hz, (30mA TRIP), TEST BUTTON, INDICATOR LIGHT, SHUTTERED CONTACTS, IP 20 RATED, GLAND TYPE CABLE ENTRY, HORIZONTAL MOUNT, ACCEPTS EUROPEAN, INTERNATIONAL, UK, BRITISH, AUSTRALIA, ASIA, THAILAND, NEMA 5-15P, 6-15P, 5-20P, 6-20P PLUGS. GRAY.
Notes:
* Downstream outlets can be protected. Use on single phase 230 volt circuits only.
* Latched RCD, No reset after power failure. RCBO (single pole + neutral) provides over current protection.
* View Dimensional Data Sheet for mating European, International plug types.
* Not for use on life support, medical equipment, refrigeration equipment.
* GFCI (RCBO/RCD) outlets are available for all countries.